August 1, 2014

More on MySQL transaction descriptors optimization

Since my first post on MySQL transaction descriptors optimization introduced in Percona Server 5.5.30-30.2 and a followup by Dimitri Kravchuk, we have received a large number of questions on why the benchmark results in both posts look rather different. We were curious as well, so we tried to answer that question by retrying benchmarks on […]

Virident tachIOn: New player on Flash PCI-E cards market

(Note: The review was done as part of our consulting practice, but is totally independent and fully reflects our opinion) In my talk on MySQL Conference and Expo 2010 “An Overview of Flash Storage for Databases” I mentioned that most likely there are other players coming soon. I actually was not aware about any real […]

FlashCache: tpcc workload with FusionIO card as cache

This run is very similar what I had on Intel SSD X25-M card, but now I use FusionIO 80GB SLC card. I chose this card as smallest available card (and therefore cheapest. On Dell.com you can see it for about $3K). There is also FusionIO IO-Xtreme 80GB card, which is however MLC based and it […]

FlashCache: tpcc workload

This is my last post in series on FlashCache testing when the cache is placed on Intel SSD card. This time I am using tpcc-like workload with 1000 Warehouses ( that gives 100GB of data) on Dell PowerEdge R900 with 32GB of RAM, 22GB allocated for buffer pool and I put 70GB on FlashCache partition […]

FlashCache: first experiments

I wrote about FlashCache there, and since that I run couple benchmarks, to see what performance benefits we can expect. For initial tries I took sysbench oltp tests ( read-only and read-write) and case when data fully fits into L2 cache. I made binaries for FlashCache for CentOS 5.4, kernel 2.6.18-164.15, you can download it […]

FusionIO – time for benchmarks

I posted about FusionIO couple times RAID vs SSD vs FusionIO and Testing FusionIO: strict_sync is too strict…. The problem was that FusionIO did not provide durability or results were too bad in strict mode, so I lost interest FusionIO for couple month. But I should express respect to FusionIO team, they did not ignore […]

RAID vs SSD vs FusionIO

In benchmarks passion (see my two previous posts) I managed to setup all three devices (RAID was on board; Intel X25-E SSD connected to HighPoint controller, FusionIO card) on our working horse Dell PowerEdge R900 (btw, to do that I had to switch from CentOS 5.2 to Ubuntu 8.10, as CentOS was not able to […]

SSD, XFS, LVM, fsync, write cache, barrier and lost transactions

We finally managed to get Intel X25-E SSD drive into our lab. I attached it to our Dell PowerEdge R900. The story making it running is worth separate mentioning – along with Intel X25-E I got HighPoint 2300 controller and CentOS 5.2 just could not start with two RAID controllers (Perc/6i and HighPoint 2300). The […]

Evaluating IO subsystem performance for MySQL Needs

I’m often asked how one can evaluate IO subsystem (Hard drive RAID or SAN) performance for MySQL needs so I’ve decided to write some simple steps you can take to get a good feeling about it, it is not perfect but usually can tell you quite a lot of what you should expect from the […]

Database problems in MySQL/PHP Applications

Article about database design problems is being discussed by Kristian. Both article itself and responce cause mixed feellings so I decided it is worth commenting: 1. Using mysql_* functions directly This is probably bad but I do not like solutions proposed by original article ether. PEAR is slow as well as other complex conectors. I […]